G6B
TECHNICAL DATA G6B – Conform EEC directive 2016/426 – SIDE MOUNTING
Fuel : | Natural gas |
Propane / Butane | |
Burner capacity : | 20 – 60 kWatt |
Mode of control : | On / Off |
Safety device on burner : | BRAHMA controller |
Flame monitoring : | Ionisation |
Nominal motor capacity : | 165 Watt |
Nominal voltage : | 220 V – 50 / 60 Hz |
Gas supply : | 3/8” – 1/2 “ |
Natural gas : 400 – 500 mB | |
Propane / Butane : 35 – 50 mB | |
Gas valve : double | 220 V – 50 / 60 Hz – 36 Watt |
Max pressure : 500 mB | |
Operation heat values : | Natural Gas Low : Hu = 8.83 kWh / Nm³ |
Natural Gas High : Hu= 10.35 kWh / Nm³ | |
Butane : Hu = 34.29 kWh / Nm³ | |
Propane : Hu = 25.9 kWh / Nm³ | |
Dimensions : | H 630 x W 325 x D 250 mm |
Weight : | Net 18 Kg – Gross 19 Kg |
TECHNICAL DATA SAFETY DEVICE
Nominal Voltage : | 220 V – 50 / 60 Hz |
Ignition time : | 1.5 sec |
Shut – off time : | 5 sec |
Start and Run signal : | IN : 220 V |
Burner heating signal : | OUT : 220 |
Generated alarms : | OUT : 220 V |
Indications : | WHITE : burner heating |
RED : burner in alarm |
G6B – Replaces side mounted Venturi burners
(All Antonini types, Eclipse etc.)
MECHANICAL MOUNTING :
Burner :
Roof mounted with a plate of 250 x 250 mm.
Fixing holes at 220 x 220 mm.
– The mounting plate and holes can be adapted to any dimension.
GAS SUPPLY :
A stainless steel flexible tube links to the existing gas taps 3/8 “
– The burner runs on the existing type of gas and pressure.
ELECTRIC CONNECTIONS :
The ‘Harting 6 pole male connector’ links to the cable coming from the main panel, same pin layout.
ELECTRIC SIGNALS :
The Brahma controller accepts and sends back all signals from and to the panel.
BURNERS :G5–G6B –G7
REALISATION & RESULTS