TECHNICAL DATA G6B – Conform EEC directive 2016/426 – SIDE MOUNTING

Fuel :Natural gas
 Propane / Butane
Burner capacity :20 – 60 kWatt
Mode of control :On / Off
Safety device on burner :BRAHMA controller
Flame monitoring :Ionisation
Nominal motor capacity :165 Watt
Nominal voltage :220 V – 50 / 60 Hz
Gas supply :3/8” – 1/2 “
 Natural gas : 400 – 500 mB
 Propane / Butane : 35 – 50 mB
Gas valve : double220 V – 50 / 60 Hz   – 36 Watt
 Max pressure : 500 mB
Operation heat values :Natural Gas Low : Hu = 8.83 kWh / Nm³
 Natural Gas High : Hu= 10.35 kWh / Nm³
 Butane : Hu = 34.29 kWh / Nm³
 Propane : Hu = 25.9 kWh / Nm³
Dimensions :H 630 x W 325 x D 250 mm
Weight :Net 18 Kg – Gross 19 Kg

TECHNICAL DATA SAFETY DEVICE

Nominal Voltage :220 V – 50 / 60 Hz
Ignition time :1.5 sec
Shut – off time :5 sec
Start and Run signal :IN : 220 V
Burner heating signal :OUT : 220
Generated alarms :OUT : 220 V
Indications :WHITE : burner heating
 RED : burner in alarm

G6B – Replaces side mounted Venturi burners
(All Antonini types, Eclipse etc.)

MECHANICAL MOUNTING :

Burner :                       
Roof mounted with a plate of 250 x 250 mm.
Fixing holes at 220 x 220 mm.
– The mounting plate and holes can be adapted to any dimension.

GAS SUPPLY :

A stainless steel flexible tube links to the existing gas taps 3/8 “
– The burner runs on the existing type of gas and pressure.

ELECTRIC CONNECTIONS :

The ‘Harting 6 pole male connector’ links to the cable coming from the main panel, same pin layout.

ELECTRIC SIGNALS :

The Brahma controller accepts and sends back all signals from and to the panel.


BURNERS :G5G6B G7